Description
Approved Standards
Agency | Standard | File No. | Approved models |
---|---|---|---|
TÜV Rheinland | EN 60947-5-1 | R9551015, J9951016 | Ask your OMRON representative for information on approved models. |
CCC | – | – | |
UL | – | – |
Ratings
Rated voltage |
Standard load | Micro load | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Non-inductive load (A) | Inductive load (A) | Non-inductive load (A) | ||||||||
Resistive load | Lamp load | Inductive load | Motor load | Resistive load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | NC | NO | |
8 VDC 14 VDC 30 VDC |
1 1 1 |
– – – |
1 1 1 |
– – – |
0.1 0.1 0.1 |
Minimum applicable load |
Standard load | Micro load |
---|---|---|
160 mA at 5 VDC | 1 mA at 5 VDC |
Inrush current | NC | 10 A max. |
---|---|---|
NO | 10 A max. |
Note: 1. The above current ratings are for a standard current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Approved Standard Ratings
TÜV (EN 60947-5-1)
Model | Applicable category and ratings |
Thermal current (Ithe) |
||
---|---|---|---|---|
I | II | III | ||
1 2 |
[] [] |
21/22 21/22 |
DC-12 1 A/30 VDC DC-12 0.1 A/30 VDC |
1A 0.1A |
Note: 1. []:Actuator variation of item II
2. DC-12 1 A/30 VDC means as follows:
Applicable category: DC-12
Rated operating current (Ie): 1 A
Rated operating voltage (Ue): 30 VDC
Characteristics (Standard Load Model and Micro Load Model)
Degree of protection | IP67 (IEC 60529) and IP67G (JIS C 0920 Annex 1) *1 Passed OMRON’s Oil-resistant Component Evaluation Standards *2 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) |
|
---|---|---|
Durability | Mechanical | 4,000,000 operations min. |
Electrical | 500,000 operations min. (Standard load: 1 A at 30 VDC, resistive load/Micro load: 0.1 A at 30 VDC, esistive load) 4,000,000 operations min. (10 mA at 24 VDC, resistive load) |
|
Operating speed | 0.1 mm/sec to 0.5 m/sec | |
Operating frequency | Mechanical: 120 operations/min Electrical: 30 operations/min |
|
Insulation resistance | 100 MΩ min. (at 500 VDC) *3 | |
Contact resistance | Standard load: D4ER-1[][][]N[]: 15 mΩ max. (initial value for the built-in switch whentested alone) Micro load: D4ER-2[][][]N[]: 50 mΩ max. (initial value for the built-in switch whentested alone) |
|
Dielectric strength |
Between terminals of same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and noncurrent-carrying metal part |
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN 60947-5-1) |
|
Rated insulation voltage (Ui) | 250 V | |
Pollution degree (operating environment) |
3 (EN 60947-5-1) | |
Short-circuit protective device (SCPD) |
10 A fuse (type gG or type gI, IEC 60269 approved) | |
Conditional short-circuit current | 100 A (EN 60947-5-1) | |
Conventional enclosed thermal current (Ithe) |
5 A (EN 60947-5-1) | |
Protection against electric shock | Class II (grounding not required with double insulation) | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction | 1,000 m/s2 max. (IEC 68-2-27) |
Malfunction | 300 m/s2 max. (IEC 68-2-27) | |
Ambient operating temperature/Ambient storage temperature |
5°C to 70°C (with no icing or condensation) | |
Ambient operating humidity | 35% to 95%RH (with no condensation) | |
Weight | (in case of roller plunger) Cable type (2 m): Approx. 140 g Pre-wired Connector type: Approx. 103 g |
Reviews