Description
Approved Standards
Agency | Standards | File No. | Approved models |
---|---|---|---|
TÜV Rheinland | EN60947-5-1 (IEC947-5-1) |
J50062491 | Only models with ground terminals |
CCC (CQC) | GB/T14048.5 | Contact your OMRON representative for details. |
Ask your OMRON representative for information on approved models. |
Ratings
Standard Model
Rated voltage | Resistive load | |
---|---|---|
NC | NO | |
125 VAC 250 VAC |
10 A 10 A |
|
125 VDC 250 VDC |
0.6 A 0.3 A |
Note: The above currents are steady-state currents.
Inrush current | NC | 24 A max. |
---|---|---|
NO | 24 A max. |
Micro Load Ratings
Rated voltage | Resistive load |
---|---|
125 VAC | 0.1 A |
8 VDC 30 VDC |
Approved Standard Ratings
TÜV (EN60947-5-1) (Grand terminal models only)
Standard Model
Applicable category | AC-15 | DC-15 |
---|---|---|
Rated operating current (Ie) | 2 A | 2 A |
Rated operating voltage (Ue) | 250 V | 48 V |
Micro Load Model
Applicable category | AC-14 | DC-15 |
---|---|---|
Rated operating current (Ie) | 0.1 A | 0.1 A |
Rated operating voltage (Ue) | 125 V | 30 V |
CCC (GB/T14048.5)
Applicable category and ratings |
---|
AC-15 2 A/250 VAC |
Characteristics
Degree of protection | IP67 | |
---|---|---|
Durability * | Mechanical | 5,000,000 operations min. |
Electrical | 300,000 operations min. (10 A at 250 VAC, resistive load) | |
Operating speed | 0.1 mm to 0.5 m/s | |
Operating frequency |
Mechanical | 120 operations min. |
Electrical | 30 operations min. | |
Rated frequency | 50/60 Hz (AC) | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value) | |
Dielectric strength |
Between terminals of same polarity | 1,000 VAC/Uimp 4,000 VAC |
Between current-carrying metal parts and ground |
1,500 VAC/Uimp 4,000 VAC | |
Between each terminal and non- current-carrying metal part |
1,500 VAC/Uimp 4,000 VAC | |
Between terminals of different polarity | Uimp 4 kV (EN60947-5-1) | |
Rated insulation voltage (Ui) | 300 VAC (EN60947-5-1) | |
Switching overvoltage | 1,000 V max. (EN60947-5-1) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gG or gI (IEC269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 5 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Insulation class I (Use the grounding terminal or ground on the machine side.) | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction | 1,000 m/s2 min. |
Malfunction | 200 m/s2 min. | |
Ambient operating temperature | -10°C to 80°C (with no icing) | |
Ambient operating humidity | 35% to 95% | |
Weight | Approx. 580 g (in the case of VB-4211) |
Reviews
There are no reviews yet.