testo 300 Longlife kit 1 with printer – Flue gas analyzer (O2, CO up to 4,000 ppm, NO – can be retrofitted)

  • Intuitive, smart, efficient: intuitive measurement menus, fast-response Smart-Touch operation, efficient, wireless parallel measurement of up to four testo Smart Probes, practical second screen function, on-site documentation, e-mailing of reports
  • Including O2 and CO sensor up to 4,000 ppm (NO sensor – can be retrofitted)
  • High-quality sensor technology with up to 6 years’ service life
  • In the kit: testo 300 Longlife flue gas analyzer, including O2 and CO sensor up to 4,000 ppm, mains unit, basic flue gas probe, spare dirt filters, testo Bluetooth® printer, spare thermal paper, EasyHeat software, case

Description

Details

Product Description
Carry out installation and maintenance work on heating systems several times a day using the flue gas analyzer with Longlife sensors. The TÜV-tested testo 300 Longlife flue gas analyzer is supplied with O2 and CO sensor up to 4,000 ppm (NO – can be retrofitted), basic flue gas probe, testo Bluetooth® printer, case and practical accessories.
Delivery Scope
  • testo 300 Longlife flue gas analyzer with O2 and CO sensor up to 4,000 ppm, NO – can be retrofitted (0633 3004 72)
  • USB mains unit, including cable (0554 1106)
  • Compact basic flue gas probe, 180 mm, Ø 6 mm, Tmax. 500°C; 1.5 m hose; including dirt filters and cone for fixing (0600 9740)
  • Spare dirt filters, compact probe; 10 off (0554 0040)
  • BLUETOOTH®/IRDA printer, including 1 roll of thermal paper and rechargeable battery (0554 0621)
  • Spare thermal paper for printer, indelible ink (0554 0568)
  • Free download EasyHeat PC software (0554 3332)
  • Instrument case (height: 130 mm) for instrument, probes and accessories (0516 3300)
testo 300 Longlife – Flue gas analyzer (O2, CO up to 4,000 ppm, NO – can be retrofitted)
General technical data
Operating humidity 15 to 90 %RH non-condensing
Weight approximately 800 g
Dimensions 244 (including probe connection) x 98 x 59 mm (LxWxH)
Operating temperature -5 to +45 °C
Protection class IP40
Product colour black/orange
Display type 5.0″ touch display, HD 1280*720 pixels, IPS (160 k)
Power supply Rechargeable battery, USB mains unit
Warranty conditions
Authorizations TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3
Guarantee Gas sensors (O₂, CO) 48 months; NO, NOlow, COlow sensor 24 months; rechargeable battery: 12 months; Thermocouple 12 months
Memory 1,000,000 measuring values
Storage battery type Lithium ion battery
Battery life 10 h
Storage temperature -20 to +50 °C
Charging temperature 0 to +45 °C
Temperature – TC Type K (NiCr-Ni)
Measuring range -40 to +1200 °C
Accuracy ±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution 0.1 °C (-40 to +999.9 °C)

1 °C (Remaining Range)

Differential Pressure – Piezoresistive
Measuring range -100 to +200 hPa
Accuracy ±0.5 hPa (0 to +50.0 hPa)

±1 % of mv (+50.1 to +100.0 hPa)

±1.5 % of mv (+100.1 to +200 hPa)

Resolution 0.01 hPa
Flue gas O₂
Resolution 0.1 Vol.%
Flue gas COlow (with H₂-compensation)
Measuring range 0 to 500 ppm
Accuracy ±2 ppm (40 to +500 ppm)

±5 % of mv Remaining Range

Resolution 0.1 ppm
Flue gas NO
Measuring range 0 to 3000 ppm
Accuracy 5 to 0 ppm

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution 1 ppm
Flue gas Nolow
Measuring range 0 to 300 ppm
Accuracy ±2 ppm (0 to +39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution 0.1 ppm
Differential Pressure flue gas Draught – Piezoresistive
Measuring range -9.99 to +40 hPa
Accuracy ±0.005 hPa (+0 to +0.1 hPa)

±0.02 hPa (0.1 to +3.00 hPa)

±1.5 % of mv (3.01 to +40 hPa)

Resolution 0.001 hPa (0 to 0.1 hPa)

0.01 hPa (Remaining Range)

Flue gas degree of effectivity, Eta (calculated)
Measuring range 0 to 120 %
Resolution 0.1 %
Flue gas loss (calculated)
Measuring range 0 to 99.9 %
Resolution 0.1 %
Flue gas CO₂ calculation (calculated from O₂)
Measuring range Display range 0 to CO₂ max
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Flue gas CO (without H₂-compensation)
Measuring range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution 1 ppm
Ambient CO
Measuring range 0 to 2000 ppm
Accuracy ±10 ppm (0 to 100 ppm)

±10 % of mv (101 to 2000 ppm)

Resolution 1 ppm
Differential Pressure 4 Pa measurement – Piezoresistive
Measuring Range -50 to +50 Pa
Accuracy ±0.3 Pa (< 10 Pa)

±3 % of mv (Remaining Range)

Resolution 0.1 Pa
Compact basic flue gas probe, 180 mm, Ø 6 mm, Tmax 500 °C
General technical data
Diameter probe shaft 6 mm
Cable length 1.5 m
Length probe shaft 180 mm
Product colour Black
Temperature maximum 500 °C
Diameter 6 mm
Weight 346 g
Spare thermal paper for printer
General technical data
Dimensions 120 x 75 x 60 mm
Product-/housing material paper
Product colour white
Weight 50 g
testo EasyHeat v2.12 SP6 – PC software
General technical data
System requirements Windows® 7; Windows® 8; Windows® 10
Instrument case (height: 130 mm) – for instrument, probes and accessories
General technical data
Weight 3880 g
Dimensions 520 x 400 x 130 mm (LxWxH)
Product-/housing material Plastic
Product colour Black
USB mains unit with cable
General technical data
Weight 144 g
Dimensions 85 x 55 x 90 mm LxWxH
Product colour Black
Cable length 2 m
Power supply 230 V AC / 5 V DC (2 A), micro USB, for the use in USA, CA, AU, Europe, UK, CN, Korea

Reviews

There are no reviews yet.

Be the first to review “testo 300 Longlife kit 1 with printer – Flue gas analyzer (O2, CO up to 4,000 ppm, NO – can be retrofitted)”