Solid-state Timer H3DS

• A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC with H3DS-XL[])

• Smart Dial/Selector-locking Mechanism: Prevents the dials and selectors on the Timer’s front panel from being inadvertently operated or being operated without authorization. The lock can only be unlocked and locked with an optional pen-type Lock Key.

• Screw-Less Clamp type available. (H3DS-[]LC)

• Sticker provided for easy timer identification and management.

• Terminal clamp left open when delivered (screw terminal type).

• Finger protection terminal block to meet VDE0106/P100.

• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.

• Incorporates environment-friendly, cadmium-free contacts.

• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.

Category: Tag:

Description

General

 

Item H3DS-ML[] H3DS-SL[] H3DS-AL[]
Operating mode A: ON-delay (Signal or Power)
B: Flicker OFF start (Signal or Power)
B2: Flicker ON start (Signal or Power)
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON/OFF-delay
J: One-shot (Signal or Power)
A: ON-delay
B2: Flicker ON start
E: Interval
J: One-shot
A: ON-delay (fixed)
Input type Voltage input
Output type Relay: SPDT
External connections Screw terminal, Screw-Less Clamp
Terminal block Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves.
Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves.
Terminal screw
tightening torque
0.98 Nm max.
Mounting method DIN track mounting *
Attachment Nameplate label
Approved standards UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5 A/AC-14; 250 V 1 A/AC-15;
250 V 1 A/DC-13; 30 V 0.1 A/DC-14; 30 V 0.05 A)

 

* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

Time Ranges

 

Time scale display Time range
0.1 s 0.1 to 1.2 s
1 s 1 to 12 s
0.1 m 0.1 to 1.2 min
1 m 1 to 12 min
0.1 h 0.1 to 1.2 h
1 h 1 to 12 h
10 h 10 to 120 h

 

Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.

Ratings

 

Rated supply voltage *1, *2 24 to 230 VAC (50/60 Hz)/24 to 48 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 2.4 VAC/DC max.
Power consumption *3 AC:
32 VA max./3.0 W max. (typical: 30 VA/2.7 W) at 230 VAC
DC:
0.7 W max. (typical: 0.6 W) at 24 VDC
1.4 W max. (typical: 1.3 W) at 48 VDC
Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF
Load connectable in parallel with inputs (terminals B1 and A1).
H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC
L-level: 0 to 2.4 VAC/DC
Control output Contact output:
5 A at 250 VAC with resistive load (cosφ = 1)
1 A at 250 VAC with inductive load (cosφ = 0.3)
5 A at 30 VDC with resistive load (cosφ = 1)
0.15 A max. at 125 VDC with resistive load,
0.1 A max. at 125 VDC with L/R of 7 ms.
The minimum applicable load is 10 mA at 5 VDC (P reference value).
Contact materials: Ag-alloy
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

 

 

*1. DC ripple rate: 20% max.
*2. Since an inrush current of 0.5 A will occur when using the power supply voltage at 24 VDC, pay careful attention
when turning on or off the power supply to the Timer with a solid-state output such as a sensor.
*3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The
power consumption of the H3DS-ML includes the input circuit with the B1 and A1 terminals short-circuited.

 

Characteristics

 

Accuracy of operating
time
±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% ±50 ms max. of FS
Signal input time 50 ms min.
Influence of voltage ±0.7% max. of FS (±0.7% ±10 ms max. at 1.2-s range)
Influence of
temperature
±5% max. of FS (±5%±10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000
VAC for 1 min.
Between control output terminals and operating circuit: 2,000 VAC for 1 min.
Between contacts not located next to each other: 1,000 VAC for 1 min.
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 100 m/s2 3 times each in 6 directions
Destruction: 1,000 m/s2 3 times each in 6 directions
Impulse withstand
voltage
5 kV (between power terminals)
5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) *
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
Immunity Surge: IEC61000-4-5
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Voltage Dip/Interruption: IEC61000-4-11
Case color Light gray (5Y7/1)
Degree of protection IP30 (Terminal block: IP20)
Weight Approx. 70 g

 

 

* For reference:
In both cases, a life of 100,000 operations can be expected.

 

H3DS-F

General

 

Item H3DS-F
Operating mode Flicker-OFF/Flicker-ON start
Output type Relay: SPDT
External connections Screw terminal, Screw-Less Clamp
Terminal block Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves.
Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves.
Terminal screw
tightening torque
0.98 Nm max.
Mounting method DIN track mounting *
Attachment Nameplate label
Approved standards UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13;
30 V 0.1 A)

 

* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

Time Ranges

 

Time scale display Time range
0.1 s 0.1 to 1.2 s
1 s 1 to 12 s
0.1 m 0.1 to 1.2 min
1 m 1 to 12 min
0.1 h 0.1 to 1.2 h
1 h 1 to 12 h

 

Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.

Ratings

 

Rated supply voltage * 24 to 230 VAC (50/60 Hz)/24 to 48 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 2.4 VAC/DC max.
Power consumption AC:
33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC
DC:
0.7 W max. (typical: 0.6 W) at 24 VDC
1.4 W max. (typical: 1.2 W) at 48 VDC
Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF
Load connectable in parallel with inputs (terminals B1 and A1).
H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC
L-level: 0 to 2.4 VAC/DC
Control output Contact output:
5 A at 250 VAC with resistive load (cosφ = 1)
1 A at 250 VAC with inductive load (cosφ = 0.3)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

 

* DC ripple rate: 20% max.

Characteristics

 

Accuracy of operating
time
±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% ± 50 ms max. of FS
Influence of voltage ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)
Influence of
temperature
±5% max. of FS (±5% ± 10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000
VAC (50/60 Hz) for 1 min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
Impulse withstand
voltage
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 200 m/s2, 3 times each in 6 directions
Destruction: 300 m/s2, 3 times each in 6 directions
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) *
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz)
(level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port
with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3)
Case color Light gray (5Y7/1)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 70 g

 

 

* For reference:
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

 

H3DS-G

General

 

Item H3DS-G
Operating mode Star-delta operation
Operating/Reset method Time-limit operation/Self-reset
External connections Screw terminal, Screw-Less Clamp
Terminal block Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves.
Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves.
Terminal screw tightening
torque
0.98 Nm max.
Output type (Star operation circuit) Relay: SPST-NO
(Delta operation circuit) Relay: SPST-NO
Mounting method DIN track mounting *
Attachment Nameplate label
Approved standards UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/
DC-13; 30 V 0.1 A)

 

* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

Time Ranges

 

Time scale Star operation time ranges
x 1 1 to 12 s
x 10 10 to 120 s

 

 

Star-delta transfer time Programmable at 0.05 s, 0.1 s, 0.5 s, or 1 s

 

Ratings

 

Rated supply voltage * 24 to 230 VAC (50/60 Hz)/24 to 48 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.5 s
Reset voltage 2.4 VAC/DC max.
Power consumption AC:
21 VA max./1.7 W max. (typical: 20 VA/1.6 W) at 230 VAC
DC:
1.3 W max. (typical: 1.2 W) at 24 VDC
0.7 W max. (typical: 0.6 W) at 48 VDC
Control output Contact output:
5 A at 250 VAC with resistive load (cosφ = 1)
1 A at 250 VAC with inductive load (cosφ = 0.3)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

 

* DC ripple rate: 20% max.

Characteristics

 

Accuracy of operating
time
±1% max. of FS
Setting error ±10% ± 50 ms max. of FS
Total tolerance of
transfer time
± (25% FS + 5 ms) max.
Influence of voltage ±0.5% max. of FS
Influence of
temperature
±5% max. of FS
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000
VAC (50/60 Hz) for 1 min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
Impulse withstand
voltage
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 200 m/s2, 3 times each in 6 directions
Destruction: 300 m/s2, 3 times each in 6 directions
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) *
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz)
(level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port
with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3)
Case color Light gray (5Y7/1)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 70 g

 

 

* For reference:
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

 

H3DS-X

General

 

Item H3DS-X
Operating mode ON-delay
Operating/Reset method Time-limit operation/self-resetting
Output type SCR output
External connections Screw terminal, Screw-Less Clamp
Terminal block Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves.
Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves.
Terminal screw tightening
torque
0.98 Nm max.
Mounting method DIN track mounting *
Attachment Nameplate label
Approved standards UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

 

* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

Time Ranges

 

Time scale display Time range
0.1 s 0.1 to 1.2 s
1 s 1 to 12 s
0.1 m 0.1 to 1.2 min
1 m 1 to 12 min
0.1 h 0.1 to 1.2 h
1 h 1 to 12 h
10 h 10 to 120 h

 

Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.

Ratings

 

Rated supply voltage * 24 to 230 VAC/VDC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 1.0 VAC/VDC max.
Reset current 5 mA max.
Power consumption 5 mA max.
Control output SCR output: 5 mA to 0.7 A
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

 

* The ripple in DC power supply must be 5% max.

Characteristics

 

Accuracy of operating
time
±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% ± 50 ms max. of FS
Reset time 0.1 s max.
Influence of voltage ±0.5% max. of FS (±0.5%±10 ms max. at 1.2-s range)
Influence of
temperature
±5% max. of FS (±5%±10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000
VAC for 1 min
Impulse withstand
voltage
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±1.5 kV (between power supply terminals)
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 200 m/s2, 3 times each in 6 directions
Destruction: 300 m/s2, 3 times each in 6 directions
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz)
(level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port
with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3)
Case color Light gray (5Y7/1)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 70 g

Reviews

There are no reviews yet.

Be the first to review “Solid-state Timer H3DS”

Your email address will not be published. Required fields are marked *