D4BL

• Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.

• Die-cast aluminum body incorporating a switch box with degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.

• Equipped with a horizontal and vertical conduit outlet.

• Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a swinging door are available.

• The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.

Description

Standards and EC Directives

Conforms to the following EC Directives:

・ Machinery Directive
・ EN ISO 14119
・ EN 60204-1

Certified Standards

 

Certification body Standard File No.
TÜV Rheinland EN60947-5-1 (certified direct opening)
GS-ET-19
Consult your OMRON representative for details.
UL UL508 E76675
CSA CSA C22.2, No.14 LR45746
CQC (CCC) GB/T 14048.5 Consult your OMRON representative for details.

 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T 14048.5)

 

Type Standard model Indicator model
Utilization category AC-15 AC-15
Rated operating current (Ie) 3 A 6 A
Rated operating voltage (Ue) 250 V 115 V

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
10 A 60
30
6
3
7,200 720

 

Note: The UL/CSA certified rating for products with indicators (-A) is 6 A/115 VAC.

Characteristics

 

Interlock type Type 2 (EN ISO 14119)
Coding level Low Level coded (EN ISO 14119)
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *3 19.61 N min. (EN60947-5-1)
Direct opening travel *3 20 mm min. (EN60947-5-1)
Holding force (Fzh) 700 N min. (GS-ET-19)
Contact resistance 50 mΩ max.
Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class I (with ground terminal)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of same
polarity
4 kV
Between terminals of
different polarity
Between each terminal and
ground
Between solenoid and ground 2.5 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 10 A (EN60947-5-1)
Ambient operating temperature -10 to 55°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 800 g