Description
Ratings
Item | H5AN-4D/H5AN-4DM |
---|---|
Rated supply voltage | H5AN-4D: 100 to 240 VAC (50/60 Hz), 12 to 24, 48, or 100 VDC (permissible ripple: 20% max.) H5AN-4DM: 100 to 240 VAC (50/60 Hz), 12 to 24 VDC (permissible ripple: 20% max.) |
Operating voltage range |
85% to 110% of rated supply voltage |
Power consumption | Approx. 10 VA (at 240 VAC), approx. 5 W (at 24 VDC) |
Resetting system and gate input |
Reset by power-OFF: min. power OFF time: 0.5 s * External reset or gate (common to contact and transistor inputs): min. reset input signal width: 0.02 s |
One-shot output time | 0.1 to 1 s (adjustable) |
Control outputs | Contact output: SPDT, 3 A at 250 VAC, resistive load (cosφ = 1) Transistor output: Open collector, 100 mA max. at 30 VDC max. |
Power supply for externally connected components |
12 VDC±10%, 80 mA (permissible ripple: 5% max.) |
Case color | Light gray (Munsell 5Y7/1) |
* This does not apply to to the models ending with -M when memory backup is enabled.
Characteristics
Accuracy of operating time | ±0.01% ±0.05 s max. (power OFF start), ±0.005% ±0.03 s max. (reset start) *1 |
---|---|
Setting error | |
Influence of voltage | |
Influence of temperature | |
Insulation resistance | 100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed non- current carrying metal parts, between non-continuous contacts) |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts) |
Impulse withstand voltage | 6 kV (between power supply terminal) 6 kV (between current-carrying terminal and exposed non-current carrying metal parts) |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude |
Shock resistance | Destruction: 300 m/s2 (approx. 30G) Malfunction: 100 m/s2 (approx. 10G) |
Ambient temperature | Operating: -10°C to 55°C Storage: -25°C to 65°C |
Ambient humidity | Operating: 35% to 85% |
Life expectancy | Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) |
Degree of protection | IP-30 |
Memory backup storage method *2 |
Non-volatile memory (Number of writes: 1 million times, Data retention: 10 years) |
Weight | Approx. 360 g |
*1. This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature
changes. It includes the rise time of the power supply, and the operating time of the internal and output circuits.
*2. This applies only to the models ending with -M.
changes. It includes the rise time of the power supply, and the operating time of the internal and output circuits.
*2. This applies only to the models ending with -M.
Applicable Standards
Approved safety standards | UL508/CSA C22.2 No. 14 conforms to EN61812-1 (Pollution degree 2/overvoltage category III) CCC: GB/T 14048.5 Pollution degree 2, Overvoltage category III * |
---|---|
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption:IEC61000-4-11 |
* CCC certification requirements.
Recommended fuse | Contact Output: 021602.5 (250 VAC, 2.5 A), manufactured by Littelfuse Transistor Output: 0216.100 (250 VAC, 100 mA) manufactured by Littelfuse |
---|---|
Rated operating voltage Ue Rated operating current Ie |
Contact Output: AC-15: Ue: 250 VAC, Ie: 3 A DC-13: Ue: 30 VDC, Ie: 0.5 A Transistor Output: DC-13: Ue: 30 VDC, Ie: 0.1 A |
Rated insulation voltage | 250 V |
Rated impulse withstand voltage (altitude: 2,000 m max.) |
4 kV (at 240 VAC) |
Conditional short-circuit current | 1,000 A |