Description
Approved Standards
Agency | Standard | File No. |
---|---|---|
UL* | UL508 | E76675 |
TÜV Rheinland | EN60947-1, EN60947-5-1 | J50041904 |
CCC(CQC) | GB/T14048.5 | Contact your OMRON representative for details. |
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
10 10 |
3 2.5 |
1.5 1.25 |
10 10 |
5 3 |
2.5 1.5 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 6 0.5 0.25 |
3 3 3 0.4 0.2 |
1.5 1.5 1.5 0.4 0.2 |
6 6 5 0.05 0.03 |
5 5 5 0.05 0.03 |
2.5 2.5 2.5 0.05 0.03 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 15 A max. |
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Approved Standard Ratings
UL/CSA
A300
Voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC |
10A | 60 30 |
6 3 |
7,200 | 720 |
TÜV Rheinland (EN60947-1, EN60947-5-1), CCC (GB/T14048.5)
Applicable category and ratings |
---|
AC-12 10 A/250 VAC |
Characteristics
Degree of protections | IP67 | |
---|---|---|
Durability | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. | |
Operating speed | 0.05 mm/s to 0.5 m/s *1 | |
Operating frequency |
Mechanical | 120 operations/min |
Electrical | 20 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value for the builtin switch when tested alone) | |
Dielectric strength |
Between non-continuous terminals | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- current-carrying metal parts |
2,000 VAC, 50/60 Hz for 1 min | |
Rated insulation voltage (Ui) | 1,000 VAC | |
Pollution degree (operating environment) | 3 (IEC947-5-1) | |
Short-circuit protective device | 10 A-fuse type gG (IEC 60269) | |
Protection against electric shock | Class II | |
Proof tracking index (PTI) | 175 | |
Switch category | D (IEC335) | |
Rated operating current (Ie) | 10 A | |
Rated operating voltage (Ue) | 250 VAC | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. (in case of plunger model) *1 *2 | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 92 g (in case of ZC-Q22(21)55) |