Enclosed Switches ZE / ZV / ZV2 / XE / XV / XV2

• Z General-purpose Basic Switches are built into ZE, ZV, and ZV2 Switches. They provided high durability and high breaking capacity.

• X Basic Switches with magnetic blowout are built into XE, XV, and XV2 Switches. DC models have also been added to the series.

• Three mounting methods (side, base, and diagonal side) and many types of actuator are available.

• Terminals face the front when the cover is removed for easy connection.

• Switches with ground terminals have CE marking.

• Approved by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

 

Description

Approved Standards

 

Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No.14 LR45746
CCC (CQC) GB/T14048.5 Contact your OMRON representative for details.

 

 

Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.

 

Ratings

 

Model Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
ZE-[]
ZV-[]
ZV2-[]
125 VAC
250 VAC
480 VAC
15
15
10
3
2.5
1.5
1.5
1.25
0.75
15
15
6
5
3
1.5
2.5
1.5
0.75
125 VDC
250 VDC
0.5
0.25
0.5
0.25
0.05
0.03
0.05
0.03
XE-[]
XV-[]
XV2-[]
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5

 

 

Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steadystate current.
4. Motor load has an inrush current of 6 times the steady-state current.

 

 

Inrush current NC 30 A max.
NO 15 A max.

 

Approved Standard Ratings

UL/CSA

 

Model Rated voltage Current Horsepower
ZE 125 VAC
250 VAC
480 VAC
15 A
15 A
15 A
1/8HP
1/4HP
125 VDC
250 VDC
0.5 A
0.25 A

 

CCC (GB/T14048.5)

 

Applicable category and ratings
AC-12 10 A/250 VAC

 

Characteristics

 

Degree of protection IP65 *1
Durability *2 Mechanical Z[]: 10,000,000 operations min.
X[]: 1,000,000 operations min.
Electrical Z[]: 500,000 operations min., for 15 A, 250 VAC resistive load
X[]: 100,000 operations min., for 10 A, 125 VDC resistive load
Operating speed Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
Operating frequency Mechanical 120 operations/min
Electrical 20 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Terminal temperature rise 50°C max.
Dielectric strength Between terminals of the same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-carrying
metal part and ground
Z[]: 2,000 VAC, 50/60 Hz for 1 min
X[]: 1,500 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal part
Z[]: 2,000 VAC, 50/60 Hz for 1 min
X[]: 1,500 VAC, 50/60 Hz for 1 min
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *3
Shock resistance
*3
Destruction 1,000m/s2 max.
Malfunction 100 m/s2 max. *4
50 m/s2 max. *5
Ambient operating temperature -10°C to +80°C (with no icing)
Ambient operating humidity General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Weight Approx. 260 to 280 g