• A double seal on the head, a complete gasket cover, and other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).

• Wide standard operating temperature range:
−40°C to +100°C (standard type).

• Models with fluoro-rubber available for greater resistance to chemicals.

• Block mounting method also reduces downtime for maintenance.

• DPDT, double-break models available for complex operations.

• Approved by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved model.)

Categories: , Tag:

Description

Approved Standards

 

Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No.14 LR45746
CCC (CQC) GB/T14048.5 Contact your OMRON representative for details.

 

Note: Ask your OMRON representative for information on approved models.

Ratings

 

Type Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
SPDT double-break
(with/without indicator)
125 VAC *
250 VAC *
480 VAC
600 VAC
10
10
10
3
10
10
10
1
3
2
1.5
1
1.5
1
0.8
0.5
10
10
3
1.5
5
3
1.5
1
2.5
1.5
0.8
0.5
8 VDC
14 VDC
30 VDC
125 VDC *
250 VDC *
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
DPDT double-break
(without indicator)
125 VAC
250 VAC
480 VAC
600 VAC
5
3
1.5
1
2
1
0.5
0.4
4
2
1
0.7
3
1.5
0.8
0.5
14 VDC
30 VDC
125 VDC
250 VAC
5
3
0.4
0.2
2
1
0.1
0.05
4
2
0.4
0.2
3
1.5
0.1
0.05
DPDT double-break
(with in-dicator)
125 VAC
250 VAC
5
3
2
1
4
2
3
1.5
12 VDC
24 VDC
48 VDC
5
3
1

 

* For those with indicators, refer to the following rated voltages.

 

Item Type SPDT, Double-break DPDT, Double-break
Without indicator With indi-cator Without indicator With in-dicator
Inrush current Normally closed 30 A max.
Normally open 20 A max.

 

 

Note: 1. The above current ratings are for steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.

 

Ratings for Indicators

 

Classi-fication Indicator Model Rated voltage Leakage current Internal resistance
SPDT double-break Neon lamp D4A-0300N 125 VAC, 250 VAC Approx. 0.47 mA 150 k Ω
LED D4A-0E00N 24 VDC Approx. 1.3 mA 15 k Ω
DPDT double-break Neon lamp D4A-0L00N 125 VAC, 250 VAC Approx. 0.28 mA 240 k Ω
LED D4A-0P00N 48 VDC Approx. 1.4 mA

 

Approved Standard Ratings

UL/CSA

A600
D4A-[]1[][]N (SPDT, Double-break, Without Indicator)

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A 60
30
15
12
6
3
1.5
1.2
7,200 720

 

A300
D4A-[]3[][]N (SPDT, Double-break, With Neon Lamp)

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
10 A 60
30
6
3
7,200 720

 

B600
D4A-[]5[][]N (DPDT, Double-break, Simultaneous Operation)
D4A-[]7[][]N (DPDT, Double-break, Sequential Operation)
D4A-[]9[][]N (DPDT, Double-break, Center Neutral Operation)

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
5 A 30
15
7.5
6.0
3
1.5
0.75
0.6
3,600 360

 

CCC (GB/T14048.5)

 

Applicable category and ratings
AC-15 2 A/125 VAC

 

Characteristics

 

Degree of protection
(reference standards)
IP67 and NEMA 1, 2, 3, 4X, 5, 6P, 12, and 13
Durability
*2
Mechanical *1 SPDT, double-break, roller lever: 50,000,000 operations min.
DPDT, double-break, roller lever: 30,000,000 operations min.
Electrical SPDT, double-break: for 125 VAC, 10 A resistive load: 1,000,000 operations min.
DPDT, double-break: for 125 VAC, 5 A resistive load: 750,000 operations min.
Operating speed 1 mm/s to 2 m/s (in case of D4A-3101N roller lever model)
Operating
frequency
Mechanical 300 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC) between terminals of the same polarity, between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part
Contact resistance 25 mΩ max. (initial value)
Temperature rise 50°C max.
Dielectric
strength
Between terminals of same
polarity
1,000 VAC, 50/60 Hz for 1 min.
Between current-carrying
metal parts and ground
2,200 VAC, 50/60 Hz for 1 min. *3
Between each terminal and
non-current-carrying metal
part
2,200 VAC, 50/60 Hz for 1 min. *3
Pollution degree (operating environment) 3
Protection against electric shock Class I (with grounding terminal)
Vibration
resistance
Malfunction *4 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction 1,000 m/s2 max.
Malfunction *4 SPDT, double-break, roller lever: 600 m/s2 max.
DPDT, double-break, roller lever: 300 m/s2 max.
Ambient operating humidity 35% to 95%RH (with no icing)
Weight Approx. 290 g (in case of D4A-3101N)