Description
Details
Product Description
- User-replaceable long-life sensors with a service life of up to 6 years
- Successful TÜV inspection according to the 1st German Federal Immission Control Ordinance (BImSchV) and EN 50379, Parts 1-3
- ntegrated draught and gas zeroing. This means that the probe does not have to be removed from the flue gas duct for the zeroing
- Fresh air dilution up to 30,000 ppm upon exceeding a CO threshold value
- NO sensor for combined heat and power plants
The new testoFix probe holder is available as an accessory, so the flue gas probe is guaranteed not to lose the centre of flow once it has been found. This can be attached to the pipe quickly and easily. It holds the probe in the centre of flow and also serves as a fall-proof suspension system for the testo 330i flue gas analyzer. Incidentally, the hose between probe and measuring instrument is lighter and more flexible than before.
The future of flue gas measuring technology
The testo 330i no longer has a display. How do you make the correct adjustments to the flue gas analyzer? Where can you view the readings? What about the creation of measurement protocols? Via the testo 330i App on your smartphone. The readings are transferred from the testo 330i flue gas analyzer to the App via Bluetooth. So you always have the relevant values to hand whenever you need them. This is particularly useful when faced with larger systems or awkward measuring points as there is no need to look around corners, which can be annoying. The measurement parameters can also be set intuitively, via the App. Once you have completed the measurement, you can add comments or photos of the system to the results on site, and send them to your customer or the office via e-mail.
Requirement: iOS 7.1 / Android 4.3 or newer. Mobile end device with Bluetooth 4.0.
Delivery Scope
Technical Data
General technical data | |
---|---|
Weight | 720 g (excluding battery) |
Dimensions | 270 x 160 x 57 mm |
Operating temperature | -5 to +45 °C |
Power supply | Rech. batt. block 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A (optional) |
System requirements | requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0 |
Maximum memory | 500000 readings |
Storage temperature | -20 to +50 °C |
Differential Pressure – Piezoresistive | |
---|---|
Measuring range | 0 to 300 hPa |
Accuracy | ±0.5 hPa (0.0 to +50.0 hPa)
±1 % of mv (+50.1 to +100.0 hPa) ±1.5 % of mv (Remaining Range) |
Resolution | 0.1 hPa |
Flue gas O₂ | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
CO determination (without H₂-compensation), automatic dilution | |
---|---|
Measuring range | 0 to 15000 ppm |
Accuracy | ±200 ppm or ±20 % of mv (0 to 15000 ppm) |
Resolution | 1 ppm |
Flue gas NO | |
---|---|
Measuring range | 0 to 3000 ppm |
Accuracy | ±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
Resolution | 1 ppm |
Differential Pressure flue gas Draught – Piezoresistive | |
---|---|
Measuring range | -9.99 to +40 hPa |
Accuracy | ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Resolution | 0.01 hPa |
Temperature | |
---|---|
Measuring range | -40 to +1200 °C |
Accuracy | ±0.5 °C (0.0 to +100.0 °C)
±0.5 % of mv (Remaining Range) |
Resolution | 0.1 °C (-40 to +999.9 °C)
1 °C (Remaining Range) |
dependent on the thermocouple
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range | Display range 0 to CO₂ max |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 or ±10 % of mv (0 to 400 )
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reviews
There are no reviews yet.