Description
Ordering data
Product type description |
SLG240COM-ER-0500-02 |
Article number (order number) |
103016120 |
EAN (European Article Number) |
4030661506531 |
eCl@ss number, version 12.0 |
27-27-27-03 |
eCl@ss number, version 11.0 |
27-27-27-03 |
eCl@ss number, version 9.0 |
27-27-27-03 |
ETIM number, version 7.0 |
EC001832 |
ETIM number, version 6.0 |
EC001832 |
Approvals – Standards
Certificates |
TÜV cULus |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Master- or Slave-function |
Yes |
Enclosure material |
Aluminium |
Gross weight |
940 g |
Reaction time, maximum |
10 ms |
General data – Features
Cascadable |
Yes |
Restart interlock (manual reset) |
Yes |
Blanking function |
Yes |
Integral system diagnostics, status |
Yes |
Integral system diagnostics |
Yes |
Number of beams |
2 |
Number of fail-safe digital outputs |
2 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 62061 |
Performance Level, up to |
c |
Category |
2 |
PFH value |
8.05 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
1 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
2 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
500 mm |
Height of the protection field |
500 mm |
Range, protection field, minimum |
300 mm |
Range, protection field, maximum |
12,000 mm |
Wave length of the sensor |
880 nm |
Mechanical data – Connection technique
Termination |
Connector |
Length of cable |
100 m |
Terminal connector, Recipient |
Connector plug M12, 5-pole |
Terminal, Connector, Transmitter |
Connector plug M12, 4-pole |
Mechanical data – Dimensions
Length of sensor |
33 mm |
Width of sensor |
27.8 mm |
Height of sensor |
571 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature, minimum |
-10 °C |
Ambient temperature, maximum |
+50 °C |
Storage and transport temperature, minimum |
-25 °C |
Storage and transport temperature, maximum |
+70 °C |
Protection class |
III |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver, maximum |
10 W |
Electrical power consumption of the transmitter, maximum |
5 W |
Electrical data – Safety digital outputs
Output current, (fail-safe output), maximum |
0.25 A |
Design of control elements |
p-type |
Scope of delivery
Scope of delivery |
Kit with 2 mounting angles |
Reviews
There are no reviews yet.