Description
Details
Product Description
Delivery Scope
- testo 300 NEXT LEVEL flue gas analyzer with O2 and CO sensor up to 4,000 ppm (0633 3002 70)
- USB mains unit, including cable (0554 1106)
- Compact basic flue gas probe, 180 mm, Ø 6 mm, Tmax. 500°C; 1.5 m hose; including dirt filters and cone for fixing (0600 9740)
- testo Bluetooth® Connector (0554 3004)
- Spare dirt filters, compact probe; 10 off (0554 0040)
- Free download EasyHeat PC software (0554 3332)
- Instrument bag (0516 3001)
Technical Data
testo 300 – Flue gas analyzer (O2, CO up to 4,000 ppm)
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -40 to +1200 °C |
Accuracy | ±0.5 °C (0.0 to +100.0 °C)
±0.5 % of mv (Remaining Range) |
Resolution | 0.1 °C (-40 to +999.9 °C)
1 °C (Remaining Range) |
Differential Pressure – Piezoresistive | |
---|---|
Measuring range | -100 to +200 hPa |
Accuracy | ±0.5 hPa (0 to +50.0 hPa)
±1 % of mv (+50.1 to +100.0 hPa) ±1.5 % of mv (+100.1 to +200 hPa) |
Resolution | 0.01 hPa |
Flue gas O₂ | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Differential Pressure flue gas Draught – Piezoresistive | |
---|---|
Measuring range | -9.99 to +40 hPa |
Accuracy | ±0.005 hPa (+0 to +0.1 hPa)
±0.02 hPa (+0.1 to +3.00 hPa) ±1.5 % of mv (3.01 to +40 hPa) |
Resolution | 0.001 hPa (0 to 0.1 hPa)
0.01 hPa (Remaining Range) |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range | Display range 0 to CO₂ max |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Ambient CO | |
---|---|
Measuring range | 0 to 2000 ppm |
Accuracy | ±10 ppm (0 to 100 ppm)
±10 % of mv (101 to 2000 ppm) |
Resolution | 1 ppm |
General technical data | |
---|---|
Operating humidity | 15 to 90 %RH non-condensing |
Weight | approximately 800 g |
Dimensions | 244 (including probe connection) x 98 x 59 mm (LxWxH) |
Operating temperature | -5 to +45 °C |
Protection class | IP40 |
Product colour | black/orange |
Display type | 5.0″ touch display, HD 1280*720 pixels, IPS (160 k) |
Power supply | Rechargeable battery, USB mains unit |
Authorizations | TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3 |
Guarantee | Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months |
Warranty conditions | |
Memory | 1,000,000 measuring values |
Storage battery type | Lithium ion battery |
Battery life | 10 h |
Storage temperature | -20 to +50 °C |
Charging temperature | 0 to +45 °C |
Differential Pressure 4 Pa measurement – Piezoresistive | |
---|---|
Measuring Range | -50 to +50 Pa |
Accuracy | ±0.3 Pa (< 10 Pa)
±3 % of mv (Remaining Range) |
Resolution | 0.1 Pa |
Reviews