Description
Details
Product Description
The testo 310 has an easy-to-use menu guide, four integrated menus for flue gas, draft, CO ambient air and pressure measurements, a large, easy-to-read display and a backlight for use in all lighting conditions.
But that is by no means all. The compact flue gas analyzer has a wide range of useful features that make it the ideal companion for plumbing and heating fitters. Thanks to the built-in magnet, it can stick to almost any metal object, like a burner for example, leaving both hands free for other tasks. The sensor can be zeroed in as little as 30 seconds and the sensor filter is just as easy to replace. In addition to that, the device has a rugged design which protects it against impact and damage and an easy-to-empty condensate collection tank.
To round things off, the readings can also be transferred directly to your testo turbo printer (optional) via the analyzer’s infrared interface, allowing you to print out on site.
What’s included
testo 310 flue gas analyzer, rechargeable battery, calibration certificate for O2, CO, hPa and °C measurements, 7 in. conical sensor, silicone tube for pressure measurements, 10x particle filters, case.
Delivery Scope
Technical Data
General technical data | |
---|---|
Weight | (with probe) Approx. 700 g |
Dimensions | 201 x 83 x 44 mm |
Operating temperature | -5 to +45 °C |
Display type | LCD (Liquid Crystal Display) |
Display function | Backlit 2-line display |
Power supply | Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature | -20 to +50 °C |
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -20 to +100 °C |
Accuracy | ±1 °C |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (ambient temperature)
Temperature – TC Type J (Fe-CuNi) | |
---|---|
Measuring range | 0 to +400 °C |
Accuracy | ±1 °C (0 to +100 °C)
±1.5 % of mv (> 100 °C) |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (flue gas)
Flue gas O₂ | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | 30 s |
Differential Pressure flue gas Draught – Piezoresistive | |
---|---|
Measuring range | -20 to +20 hPa |
Accuracy | ±0.03 hPa (-3.00 to +3.00 hPa)
±1.5 % of mv (Remaining Range) |
Resolution | 0.01 hPa |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range | 0 to CO₂ max (Display range) |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | < 40 s |
Pressure measurement | |
---|---|
Measuring range | -40 to +40 hPa |
Accuracy | ±0.5 hPa |
Resolution | 0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time t₉₀ | 60 s |
Ambient CO | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time | 60 s |